MicroNet Fibre to SAS/SATA II RAID Subsystem Manuale Utente Pagina 28

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 27
FIBRE-to-SAS/SATA RAID SUBSYSTEM
28
User Manual
For PRO-90-6601 SES board:
NOTE: The upgrade process is done twice. The first time needs a
jumper in JP8. The second time does not need a jumper.
1. Power off the RAID system. Remove the SES Module. Insert a jumper in JP8 of
SES board PRO-90-6601.
2. Insert the SES module into the RAID subsystem. Connect RS232 serial cable to
the RS232 port of SES module.
3. Power on RAID subsystem. Configure terminal settings as follows:
Baud Rate: 38400
Data Bits: 8
Parity: None
Stop Bits: 1
Flow Control: None
4. Open terminal console. Type “proses upgrade”.
Vedere la pagina 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 ... 159 160

Commenti su questo manuale

Nessun commento