MicroNet Fibre to SAS/SATA II RAID Subsystem Manuale Utente Pagina 30

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 138
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 29
Fibre to SAS/SATA II RAID Subsystem
30
User Manual
NOTE: Each PSFM has one Power Supply and one Fan. PSFM 1 has
Power#1 and Fan#1, and PSFM 2 has Power#2 and Fan#2. When the
Power Supply of a PSFM fails, the PSFM need not be removed from
the slot if replacement is not yet available. The fan will still work and
provide necessary airflow inside the enclosure.
In replacing the failed PSFM, refer to section 6.3.2 of this manual.
NOTE: After replacing the Power Supply Fan Module and turning on
the Power On/Off Switch of the PSFM, the Power Supply will not
power on immediately. The Fans in the PSFM will spin-up until the
RPM becomes stable. When Fan RPM is already stable, the RAID
controller will then power on the Power Supply. This process takes
more or less 30 seconds. This safety measure helps prevent possible
Power Supply overheating when the Fans cannot work.